Mil-Ram's New RS 485/4-20mA 3 or 4-Wire smarter Transmitter for O2 Oxygen Gas Detection. Confined space as well as Oxygen enrichment monitoring. Long life electrochemical sensor. Now available suitable for use in SIL 2 environments.

Features: Oxygen Gas Detector

no false alarms electrochemical O2 Oxygen gas sensor technology
Self-Calibration adjusts span monthly based on sensor life curve
Auto-Gas Calibration, non-intrusive, hands-free, magnetic switches
Not affected by temperature -15 deg C to +40 deg C, stable by design
LCD display - 12 characters x 2 lines. Provides user interface with magnetic switches - no dip switches
Offsite sensor calibration with memory chip embedded in sensor
Peak value, 15-min. TWA, Remaining Sensor Life, Replace Sensor indication and number days since last gas calibration
Optional Relay Module in same enclosure with low, mid, high and fault relays
Can be used with Mil-Ram's Wireless Telemetry System
Available suitable for use in SIL 2 environments
Continuous advanced Diagnostics


Specifications: Oxygen Gas Detector

Detection Range 0.0-25.0 %Vol. O2 Gas
Resolution 0.1 %Vol. O2
Response Time < 30 sec to 90% of final reading
Recovery Time < 30 sec. to 90% recovery
Temperature Range -15 deg.C to +40 deg.C
Humidity Range 15-95% RH, non-condensing, continuous
Power Requirement 12V or 15-30VDC; 1.08W @24VDC
Output 4-20mA linear. Optional Modbus RTU. Optional Relays; low, mid, high & fault.
Long life 12 to 18 months typical under normal operating conditions