» TA-2100 Transmitter

» TA-2102 Transmitter

» Control Panels

» Gas List

» Cal Kits

» Site Map





Data Sheet

Literature


HBr Gas

Detector


QUOTE REQUEST

TA-2100 Hydrogen Bromide HBr Gas Detector

Mil-Ram's New RS 485/4-20mA 3 or 4-Wire smarter Transmitter for Hydrogen Bromide HBr Gas Detection. Sensor chemistry eliminates common interfering gases. Mil-Ram patented technology eliminates zero drift and corresponding false alarms. Now available suitable for use in SIL 2 environments.

Features: Hydrogen Bromide Gas Detector

no false alarms Mil-Ram patented Hydrogen Bromide HBr gas sensor technology
Self-Calibration adjusts span monthly based on sensor life curve
Auto-Gas Calibration, non-intrusive, hands-free, magnetic switches
Not affected by temperature -25 deg C to +50 deg C, stable by design
LCD display - 12 characters x 2 lines. Provides user interface with magnetic switches - no dip switches
Offsite sensor calibration with memory chip embedded in sensor
Peak value, 15-min. TWA, Remaining Sensor Life, Replace Sensor indication and number days since last gas calibration
Optional Relay Module in same enclosure with low, mid, high and fault relays
Can be used with Mil-Ram's Wireless Telemetry System
Available suitable for use in SIL 2 environments
Continuous advanced Diagnostics


Specifications: Hydrogen Bromide Gas Detector

Detection Range 0.0 - 20.0 PPM HBr Gas
Resolution 0.1 PPM HBr
Response Time < 60 sec to 90% of final reading
Recovery Time < 30 sec. to 90% recovery
Temperature Range -25 deg.C to +50 deg.C
Humidity Range 10-95% RH, non-condensing, continuous
Zero Drift < 0.1 PPM
Power Requirement 12V or 15-30VDC; 1.08W @24VDC
Output 4-20mA linear. Optional Modbus RTU. Optional Relays; low, mid, high & fault.
Long life >3 years typical under normal operating conditions