TA-2100 F2 Fluorine Gas Detector

Mil-Ram's New RS 485/4-20mA 3 or 4-Wire smarter Transmitter for F2 Fluorine Gas Detection. Sensor chemistry eliminates common interfering gases. Mil-Ram patented technology eliminates zero drift and corresponding false alarms. Now available suitable for use in SIL 2 environments.

Features: Fluorine Gas Detector

no false alarms Mil-Ram patented Fluorine gas sensor technology
Self-Calibration adjusts span monthly based on sensor life curve
Auto-Gas Calibration, non-intrusive, hands-free, magnetic switches
Not affected by temperature -25 deg C to +50 deg C, stable by design
LCD display - 12 characters x 2 lines. Provides user interface with magnetic switches - no dip switches
Offsite sensor calibration with memory chip embedded in sensor
Peak value, 15-min. TWA, Remaining Sensor Life, Replace Sensor indication and number days since last gas calibration
Optional Relay Module in same enclosure with low, mid, high and fault relays
Can be used with Mil-Ram's Wireless Telemetry System
Available suitable for use in SIL 2 environments
Continuous advanced Diagnostics


Specifications: Fluorine Gas Detector

Detection Range 0.0-5.0 PPM Fluorine Gas
Resolution 0.1 PPM Fluorine Gas
Response Time < 45 sec to 90% of final reading
Recovery Time < 30 sec. to 90% recovery
Temperature Range -25 deg.C to +50 deg.C
Humidity Range 10-95% RH, non-condensing, continuous
Zero Drift < 0.1 PPM
Power Requirement 12V or 15-30VDC; 1.08W @24VDC
Output 4-20mA linear. Optional Modbus RTU. Optional Relays; low, mid, high & fault.
Long life >3 years typical under normal operating conditions