mil-ram

Gas Detection Systems
4135 Business Center Drive, Fremont, CA 94538
TOLL FREE: (888) 4MILRAM or (888) 464-5726

info@Mil-Ram.com

Gases
NH3
2-Wire
3-Wire
BF3
CO
2-Wire
3-Wire
HCl
2-Wire
3-Wire
F2
2-Wire
3-Wire
NO
2-Wire
3-Wire
HF
2-Wire
3-Wire
Br2
2-Wire
3-Wire
SO2
2-Wire
3-Wire
PH3
2-Wire
3-Wire
NO2
2-Wire
3-Wire
B2H6
2-Wire
3-Wire
AsF5 HCN
2-Wire
3-Wire
Cl2
2-Wire
3-Wire
SiH4
2-Wire
3-Wire
GeH4 O3
2-Wire
3-Wire
H2O2
2-Wire
3-Wire
HI
2-Wire
3-Wire
NF3 HNO3
2-Wire
3-Wire
CO2 HBr
2-Wire
3-Wire
AsH3
2-Wire
3-Wire
COCl2
N2H4
2-Wire
3-Wire
CH3Cl
H2Se ClO2
2-Wire
3-Wire
O2
2-Wire
3-Wire
H2S
2-Wire
3-Wire
BCl3 LEL
3-Wire
H2SO4
2-Wire
3-Wire
C3H3N
C2Cl4 CH3Br
POCl3 CH2F2
SiH2Cl2
C2HCl2F3
C2H4Cl2
C2HCl3
CH2Cl2
Latest Most Complete List...
View List of the Gases Detected by Mil-Ram Technology Detectors

Tox-Array 2001 TOX-ARRAY 2001 SINGLE CHANNEL CONTROLLER

The New TOX-ARRAY 2001 Microprocessor-Based, Front Panel Programmable Controller uses MIL-RAM'S no false alarms, chemically selective Toxic, LEL and O2 patented TOX-ARRAY sensors that do not react with air, have no zero drift, are not sensitive to changes in temperature, humidity or pressure and stay awake when gas is absent. Recovery is less than 30 seconds even when exposed to high gas levels and have over 3 years no maintenance life for each factory charge.

The TOX-ARRAY 2001 is a single channel controller with a 16 character X 2 line backlit LCD Display, low, mid, high and fault relays (12 amps). Relays programmable non-latching/latching, non-energized/energized and 0-255 second time delay. All parameters are field programmable (no dip switches). 85-264 VAC, 15-30VDC, 4-20mA output. Back-up battery optional. RS-485 Modbus RTU output optional. Fiberglass NEMA 4X (7-1/2"W x 9-5/8"H x 4-3/4"D) Wall Mounting Enclosure. Also available as a two-channel monitor, TOX-ARRAY 2002.

The TOX-ARRAY 2001 can be used with MIL-RAM'S new RS485/4-20mA 3 or 4-Wire Self-Calibration smarter Transmitter and the 2-Wire Loop Powered smarter Transmitter which both feature Self-Calibration, Labor-Free auto self-calibration adjusts span monthly based on life curve, Auto Calibration - auto gas calibration in 2 minutes, non-intrusive hands-free, Off-site sensor calibration to replace sensors in the field without recalibration, Remaining sensor life and replace sensor indicator, Loop Test, Peak Value, Diagnostics, Rapid Warm-Up, 12 x 2 LCD display and more. The 3 or 4-Wire smarter Transmitter offers two options - four 12-15 Amp time delay relays in the same enclosure option and RS 485 Modbus RTU option.

Can be used with Mil-Ram's Wireless Telemetry System.

 


 
The TOX-ARRAY 2001 Single Channel Controller

FEATURES

  • no false alarms - does not react with changes in temperature, humidity or pressure.
  • Patented TOX-ARRAY sensor technology.
  • Does not drift - no autozeroing or adjustments required.
  • Not affected by humidity - 5 % to 95 % relative humidity.
  • Not affected by temperature -25 deg C to +50 deg C, or -40 deg C to +50 deg C is not temperature compensated; inherent design makes it stable.
  • Maintains calibration for over six months - good practice dictates calibration be checked monthly.
  • Maintenance free - no replenishment of electrolyte or water during 3+ years of normal life of each charge.
  • Long life - over three years and is factory rechargeable over 20+ times at reasonable cost (recharge program).
  • Fast response - 90% of reading in less than 30 seconds.
  • Fast recovery - 90% recovery in less than 30 seconds.
  • Not saturated by occasional high concentrations of gas in the work environment.
  • Stays awake - does not go to sleep when it has not been exposed to gas for long periods of time.
  • Chemically selective.
  • Does not react with air.
  • No LEL, methane, hydrocarbons, Co, Co2 gas interference.
  • No sensor warm-up time.
  • Zero and Span are not interactive.
  • Single or Two Channel in a NEMA 4x enclosure.
  • 16 character x 2 line backlit LCD Display.
  • Low, mid, high and fault relays (12 amps).
  • Relays programmable/ non-latching/ latching, non-energized/ energized and D-255 second time delay.
  • Parameters are field programmable (no dip switches).
  • 85 - 264 VAC, 15-30 VDC, 4-20 mA output.
  • 4-20mA transmitters for toxic, combustibles and oxygen monitoring. Available without display and with 2, 3 or 4-wire smarter transmitters.
  • Optional battery back-up.
  • Optional RS-485 modbus RTU.
  • Can be used with Mil-Ram's Wireless Telemetry System.

NOTE: Specifications subject to change without notice.