mil-ram

Gas Detection Systems
4135 Business Center Drive, Fremont, CA 94538
TOLL FREE: (888) 4MILRAM or (888) 464-5726

info@Mil-Ram.com

Gases
NH3
2-Wire
3-Wire
BF3
CO
2-Wire
3-Wire
HCl
2-Wire
3-Wire
F2
2-Wire
3-Wire
NO
2-Wire
3-Wire
HF
2-Wire
3-Wire
Br2
2-Wire
3-Wire
SO2
2-Wire
3-Wire
PH3
2-Wire
3-Wire
NO2
2-Wire
3-Wire
B2H6
2-Wire
3-Wire
AsF5 HCN
2-Wire
3-Wire
Cl2
2-Wire
3-Wire
SiH4
2-Wire
3-Wire
GeH4 O3
2-Wire
3-Wire
H2O2
2-Wire
3-Wire
HI
2-Wire
3-Wire
NF3 HNO3
2-Wire
3-Wire
CO2 HBr
2-Wire
3-Wire
AsH3
2-Wire
3-Wire
COCl2
N2H4
2-Wire
3-Wire
CH3Cl
H2Se ClO2
2-Wire
3-Wire
O2
2-Wire
3-Wire
H2S
2-Wire
3-Wire
BCl3 LEL
3-Wire
H2SO4
2-Wire
3-Wire
C3H3N
C2Cl4 CH3Br
POCl3 CH2F2
SiH2Cl2
C2HCl2F3
C2H4Cl2
C2HCl3
CH2Cl2
Latest Most Complete List...
Mil-Ram Technology's Engineered Systems
Mil-Ram Technology, Inc. develops its own sensors and designs and packages custom systems using their Patended Tox-Array Sensors that feature no false alarms. There is a Sample-Draw option for areas that are too hot or too cold to detect gases by diffusion. Also available is a Pyrolyzer for detection of chlorofluoro-carbons (Freons- (tm) and other compounds. The D. DAS 1536 (Digital Data Acquisition System is offered for multi-point systems with capacity of 1536 points on one twisted pair of wires. All instruments, systems and transmitters can be used with Mil-Ram's Wireless Telemetry System. Features

SafEye 200 Series Open Path Gas Detector
SafEye 200 Series Open Path Gas Detector is a self-contained, fast response optical gas detection system. It detects combustible gases at concentrations lower than the explosion limit (LEL) over a "Line of Sight" of up to 460 ft. (140m) long. SafEye is the preferred system for offshore oil companies because it is immune to false alarms caused by partial blockage and extreme weather conditions (fog, rain, snow) and direct or reflected sunlight, flame and other black body radiation sources.
SafEye 300 Series IR Open Path (Line of Sight) Gas Detection System
SafEye 300 Series IR Open Path (Line of Sight) Gas Detection System provides sensitive (LEL level) monitoring of hydrocarbon gases such as methane, butane, etc. SafEye 300 Gas Detector monitors hydrocarbon gases at low concentrations over an optical path of up to 49.5ft. (30m). The system has a response time of up to 10 seconds with an option for faster gas detection of 2 seconds at short ranges.
SafEye 400 UV Open Path (Line of Sight) Gas Detection System
SafEye 400 UV Open Path (Line of Sight) Gas Detection System provides sensitive (PPM level) monitoring of Hydrogen Sulfide (H2S), Ammonia and Aromatic gases. SafEye 400 monitors toxic and aromatic gases at low concentrations over an optical path of up to 330 ft. (100m). The system has a fast response time of up to 10 seconds.
SafEye 700 Optical Open Path (line of sight) Gas Detection System
SafEye 700 Optical Open Path (line of sight) Gas Detection System employs "spectral fingerprint" analysis of the atmosphere using the Differential Optical Absorption Spectroscopy (DOAS) technique in a unique (patented) method. SafEye 700 consists of an advanced Xenon Flash infrared transmitter (source) and infrared detector (receiver), separated over a line of sight from 13 ft. (4m) up to 460 ft. (140m) to detect and quantify flammable gas presence, even when challenged by extremely harsh environments where dust, fog, rain, snow or vibration can cause a high reduction of signal.
Tox-Array 2100 - RS485 4-20mA 3 or 4-Wire Self-Calibration smarter Transmitter
The New RS485/4-20mA 3 or 4-Wire Self-Calibration smarter Transmitter features Labor-free auto self-calibration, Auto gas calibration in 2 minutes, Remaining sensor life and replace sensor indicator, Peak Value, Loop Test, Diagnostics, Backlit 12 x 2 LCD display, Off-site sensor calibration, Rapid Warm-Up and more. Optional features are four 12-15 Amp time delay relays in the same enclosure option and RS 485 Modbus RTU option.
Tox-Array 2102 – 2-Wire Loop Powered smarter Transmitter
The New 2-Wire Loop Powered smarter Transmitter features Labor-free auto self-calibration, Auto gas calibration in 2 minutes, Remaining sensor life and replace sensor indicator, Peak Value, Loop Test, Diagnostics, 12 x 2 LCD display, Off-site sensor calibration, Rapid Warm-Up and more.
D. DAS 1536 Windows Data Acquisition System
The Digital Data Acquisition System - D.DAS 1536 - provides numerous capabilities with ease of interface. It features 24-hour continuous monitoring of Toxics, Combustibles and Oxygen, is PC-based for the Tox-Array 2000 six point controllers, has up to 1536 points of detection on one twisted pair of wires, displays historical data - STELs, TWAs and real time data, and has many more features.
Tox-Array 2000 Multi-Point Controller
Microprocessor-based, programmable, for one to six channels, dedicated, .56" LED digital readouts, three alarm relays, and recorder outputs for each channel, buzzer with reset, 115/230 VAC, 12-30 VDC with option for battery backup with charger. Available with RS 485 connector. Also available with the RS485/4-20mA 3 or 4-Wire Self-Calibration smarter Transmitter - Tox-Array 2100, or the 2-Wire Loop Powered smarter Transmitter - Tox-Array 2102.
TOX-ARRAY 2000 Multi-Channel Controller XP Version
The New TOX-ARRAY 2000 - XP Version wall-mount system, front panel programmable, provides in any combination, up to 6 channels of toxic, combustible and oxygen monitoring in an Explosion-Proof Enclosure rated Class 1 GR B, C, D and NEMA 4X.
Tox-Array 2001 Single Channel Controller
The New Single Channel Controller features Microprocessor-Based, Front Panel Programmable, 16 character X 2 line backlit LCD Display, low, mid, high and fault relays (12 amps). Relays programmable non-latching/latching, non-energized/energized and 0-255 second time delay. All parameters are field programmable (no dip switches). 85-264 VAC, 15-30VDC 4-20mA output. Back-up battery optional. RS-485 Modbus RTU output optional. Fiberglass NEMA 4X Wall Mounting Enclosure. Also available with the RS485/4-20mA 3 or 4-Wire Self-Calibration smarter Transmitter - Tox-Array 2100, or the 2-Wire Loop Powered smarter Transmitter – Tox-Array 2102.
TOX-ARRAY 2001 Single Channel Controller XP Version
The New Single Channel Controller XP Version features Microprocessor-Based, Front Panel Programmable, backlit LCD Display, low, mid, high and fault relays (12 amps. All parameters are field programmable (no dip switches). 85-264 VAC, 15-30 VDC 4-20mA output. Back-up battery optional RS-485 Modbus RTU output optional. Explosion-Proof Enclosure rated Class 1, GR B, C, D and NEMA 4X; Wall Mounting.
Tox-Array 2002 Two Channel Controller
The New Two Channel Controller features Microprocessor-Based, Front Panel Programmable, Each Channel with a 16 character X 2 line backlit LCD Display, low, mid, high and fault relays (12 amps). Relays programmable non-latching/latching, non-energized/energized and 0-255 second time delay. All parameters are field programmable (no dip switches). 85-264 VAC, 15-30VDC 4-20mA Modbus RTU output. Back-up battery optional. RS-485 Modbus RTU output optional. Fiberglass NEMA 4X Wall Mounting Enclosure. Also available with the RS485/4-20mA 3 or 4-Wire Self-Calibration smarter Transmitter – Tox-Array 2100, or the 2-Wire Loop Powered smarter Transmitter – Tox-Array 2102.
TOX-BOX Single Gas Portable Instrument Toxic/LEL/O2/VOC Gases
Sample drawing single gas portable gas detection instrument. Available with any MIL-RAM Toxic/LEL/VOC/Oxygen sensor; electrochemical/catalytic/infrared/PID. Local alarms and relay outputs. Housed in a rugged, weather-proof plastic instrument case for dependable service under demanding field conditions. 
TOX-BOX Natural Gas Pipeline Portable Analyzer Carbon Dioxide, CO2
Sample drawing single gas portable gas detection instrument. Provides high resolution measurement of Carbon Dioxide gas utilizing MIL-RAM'S non-dispersive infrared (NDIR) sensor technology. Accurately measures CO2 contaminant levels in natural gas pipelines with simple connection to a positive pressure sample line. Local alarms and relay outputs. Housed in a rugged, weather-proof plastic instrument case for dependable service under demanding field conditions.
TOX-BOX Chlorine Gas Portable Instrument Water and Waste Water Treatment
Sample drawing single gas portable gas detection instrument. Available with MIL-RAM'S unique patented electrochemical chlorine sensor with corresponding meter indication. Local alarms and relay outputs. Housed in a rugged, weather-proof plastic instrument case for dependable service under demanding field conditions.
TOX-BOX Toxic Gas Portable Instrument  VOC Gas Detection
Sample drawing VOC gas portable gas detection instrument. Provides high resolution measurement of MIL-RAM'S photoionization detector (PID) with corresponding meter indication. Local alarms and relay outputs. Housed in a rugged, weather-proof plastic instrument case for dependable service under demanding field conditions. 
TOX-BOX Wireless Telemetry Portable Instrument Toxic/LEL/O2/VOC Gases
Sample drawing single gas portable gas detection instrument. Available with any MIL-RAM Toxic/LEL/VOC/Oxygen sensor; electrochemical/catalytic/infrared/PID. Local alarms and relay outputs. Housed in a rugged, weather-proof plastic instrument case for dependable service under demanding field conditions. Utilizes 902-928 MHz wireless telemetry to transmit meter readings to central control system or another portable instrument. 
Tox-Array 1000
Tox-Array 1000 Portable Instrument
Hand-held, easy-to-operate, field-rugged portable instrument available in diffusion or sample-draw configurations. It uses the same patented Mil-Ram sensors; is warranted for three years and will not give false alarms. It weighs less than two pounds and can be strapped to your belt. One set of C-size alkaline batteries will run over 2,443 hours (over 300 8-hour shifts).
Sample Draw Gas Detection System
Used for areas that are too hot, too cold, or inaccessible. The system uses Mil-Ram's patented sensors that feature no false alarms. The system can be used with Mil-Ram’s RS485/4-20mA 3 or 4-Wire Self-Calibration smarter Transmitter - Tox-Array 2100 or the 2-Wire Loop Powered smarter Transmitter - Tox-Array 2102 featuring Labor-free auto self-calibration, Auto gas calibration in 2 minutes, Remaining sensor life and replace sensor indicator, Peak Value, Loop Test, Diagnostics, Off-site sensor calibration, Rapid Warm-Up and more.
PYROLYZER®
The Mil-Ram PROLYZER® for chlorinated and fluorinated hydrocarbons uses Mil-Ram's no false alarms patented sensors. The Pyrolyzer is available with Mil-Ram’s RS485/4-20mA 3 or 4-Wire Self-Calibration smarter Transmitter – Tox-Array 2100 or the 2-Wire Loop Powered smarter Transmitter – Tox-Array 2102 featuring Labor-free auto self-calibration, Auto gas calibration in 2 minutes, Remaining sensor life and replace sensor indicator, Peak Value, Loop Test, Diagnostics, Off-site sensor calibration, Rapid Warm-Up and more.
Calibration Kits and Gases
Calibration Kits and replacement cylinders for use in calibrating Mil-Ram's no false alarms, chemically selective Toxic, LEL and O2 patented sensors that do not react with air, have no zero drift, are not sensitive to changes in temperature, humidity or pressure and stay awake when gas is absent. Recovery is less than 30 seconds even when exposed to high gas levels and have over three years no maintenance life for each factory charge.
 