mil-ram

Gas Detection Systems
4135 Business Center Drive, Fremont, CA 94538
TOLL FREE: (888) 4MILRAM or (888) 464-5726

info@Mil-Ram.com

Gases
NH3
2-Wire
3-Wire
BF3
CO
2-Wire
3-Wire
HCl
2-Wire
3-Wire
F2
2-Wire
3-Wire
NO
2-Wire
3-Wire
HF
2-Wire
3-Wire
Br2
2-Wire
3-Wire
SO2
2-Wire
3-Wire
PH3
2-Wire
3-Wire
NO2
2-Wire
3-Wire
B2H6
2-Wire
3-Wire
AsF5 HCN
2-Wire
3-Wire
Cl2
2-Wire
3-Wire
SiH4
2-Wire
3-Wire
GeH4 O3
2-Wire
3-Wire
H2O2
2-Wire
3-Wire
HI
2-Wire
3-Wire
NF3 HNO3
2-Wire
3-Wire
CO2 HBr
2-Wire
3-Wire
AsH3
2-Wire
3-Wire
COCl2
N2H4
2-Wire
3-Wire
CH3Cl
H2Se ClO2
2-Wire
3-Wire
O2
2-Wire
3-Wire
H2S
2-Wire
3-Wire
BCl3 LEL
3-Wire
H2SO4
2-Wire
3-Wire
C3H3N
C2Cl4 CH3Br
POCl3 CH2F2
SiH2Cl2
C2HCl2F3
C2H4Cl2
C2HCl3
CH2Cl2
Latest Most Complete List...
MAIN Features
The heart of any gas detection system is the Sensor. The vital signs - the operating characteristics of the Mil-Ram Tox-Array Patented sensor are of primary importance in the protection of life, protection of the environment and process controls; the process and the equipment reduces maintenance costs for maximum reliability, optimum performance and long life, and has the following features:
* No False Alarms Does not react with air, changes in temperature, humidity and/or pressure does not affect the sensor.
* Does Not Drift No auto zeroing or adjustments required.
* Not Affected by Humidity 5% to 95% relative humidity.
* Not affected by Temperature -25 deg C to +50 deg C; is not temperature compensated, its inherent design makes it stable. For NH3 and H2S: -40 deg C to +50 deg C.
* Maintains Calibration for Over Six Months Good practice dictates calibration be checked monthly.
2 minutes gas calibration.
* Maintenance-Free No replenishment of electrolyte or water added during 3+ years of normal life of each charge.
* Long Life Over 3 years and is Factory rechargeable over 20+ times at reasonable cost. (Recharge program).
* Fast Response 90% of reading in less than 30 seconds.
* Fast Recovery 90% recovery in less than 30 seconds.
* Not Saturated By occasional high concentrations of gas in the work environment.
* Stays Awake Does not go to sleep when gas is absent for long periods of time.
* Chemically Selective No interference from hydrogen, combustibles, solvent vapors.
* No Gas Interference No LEL, methane, hydrocarbons, CO, CO2 gas interference.
* Warm-Up Time No sensor warm-up time required.
* Zero and Span Zero and Span are not interactive.